Prior PL-200 Slide Loader 高通量自動(dòng)玻片裝載系統(tǒng)
Prior PL-200 Slide Loader 高通量自動(dòng)玻片裝載系統(tǒng)是一套先進(jìn)的顯微鏡玻片自動(dòng)裝載系統(tǒng),最多可放置200片玻片,結(jié)合Prior精準(zhǔn)的自動(dòng)載物平臺(tái),可完成顯微樣本自動(dòng)取相拍照,達(dá)到無人看顧,自動(dòng)換片、自動(dòng)定位、自動(dòng)拍照的目標(biāo)。PL-200可搭配四個(gè)玻片架,每個(gè)玻片架的容量可放置50個(gè)玻片,系統(tǒng)會(huì)自動(dòng)偵測(cè)感知玻片架,并且自動(dòng)判定玻片架是否被移除或安裝。當(dāng)系統(tǒng)偵測(cè)到新的玻片架時(shí),先進(jìn)的玻片偵測(cè)系統(tǒng)會(huì)自動(dòng)偵測(cè)玻片的數(shù)量及玻片的個(gè)別位置。為了確保數(shù)據(jù)的正確性可以完整的關(guān)聯(lián)到每一個(gè)玻片,并且能夠符合GoodLaboratory Practice (GLP)的要求,可再選擇搭配1D或2D的BarcodeReader使用。另外,還附帶一套完整的軟件開發(fā)工具,可以很容易的與第三方軟件進(jìn)行整合。
核心系統(tǒng) 自動(dòng)玻片裝載機(jī)(PL200) 精密電動(dòng)載物臺(tái) 控制器(V31XYZE) 操作桿(PS3J100)
可選配件 | |
PriorScientific Slide LoaderPL-200 (自動(dòng)化玻片載臺(tái))榮獲2009年LaboratoryEquipment Magazine讀者最佳票選獎(jiǎng),對(duì)于Prior所有的成員,這是最大的激勵(lì)與敬意,特別是在研發(fā)與生產(chǎn)制造部門的工作人員。
Prior PL-200(自動(dòng)化玻片載臺(tái))對(duì)于實(shí)驗(yàn)室的顯微研究領(lǐng)域提供了一個(gè)重大的進(jìn)步,它整合了Prior的H101A高精度自動(dòng)載物臺(tái),能夠做到高精度的自動(dòng)化玻片檢測(cè)應(yīng)用.
200的玻片的容量,代表的就是可以在無人操作的情況下,可以自動(dòng)化完成好幾個(gè)小時(shí)的玻片檢測(cè)工作。
關(guān)鍵性能;
The PL-100/PL-200 Slide Loaders are advanced systems for automatic slide handling in a variety of microscope applications. The PL-200 model is designed for 1×3 slides and accommodates up to 200 slides that are housed in four removable slide racks, each of which holds up to fifty slides. The PL-100 model is designed for 2×3 slides and is capable of handling up to 100 slideswhich are housed in two racks of fifty. Sensors on the loader monitor the presence of the slide racks so the system can intelligently respond when racks are changed in the middle of a run for example. Installation of a rack on the loader initiates a unique slide detection system which automatically identifies the location of the slides. Prior has optimized both to provide the highest productivity with a complete system capable of performing load/unload cycles in as little as 24s. The units can be used with existing microscopes simply by adding the appropriate Prior scanning stage.
Prepared specimen slides are precious, often unique, and need to be handled with care. In addition to the slide retaining design of the slide racks, a range of further safety features have been included in the units to minimize the risk of damage to slides. The slide gripper includes a sensor to detect the presence of a slide. If the state of this sensor changes due to an absent slide for example, the system will stop and report an error message. A similar approach is taken on the scanning stage where a sensor identifies if a slide is present on the stage. Slide scanning will not take place for example, if a slide is not successfully placed onto the stage. A third sensor is used to monitor the position of the slide relative to the stage. If the user inadvertently moves the scanning stage in the Z axis, collisions are avoided by this sensor.
英國(guó)Prior公司中國(guó)指定代理商:廣州市元奧儀器有限公司